Input Voltage.............88-264 VAC universal input Input Current.............4A@115VAC, 2A@230VAC Input Frequency...........47-63 Hz Inrush Current............15A@115VAC, 30A@230VAC PFC.......................0.98 @115VAC, 0.95 @230VAC Output Voltage............See table; ±10% adjustable Overload Protection.......105% to 135%; auto-recovery Overvoltage Protection....115% to 145% Operating Temperature.....0-40°C @100% load, -10°C @80%, 50°C @50% Safety Standards..........UL1950, EN60950 EMC Standards.............EN55022 class B, EN61000-3-2,3 EN61000-4-2,3,4,5,6,8,11 Connector.................Screw terminal block, 9P/9.5mm pitch Weight....................2.64 lb Dimensions, W*L*H.........4.53*9.06*1.97 inches
SP-300 Series
300W Single Output
Enclosed AC/DC Switchers
- Power Factor Correction (PFC)
- 88-264 VAC Universal Input
- Built-in EMI Filter
- Low Ripple & Noise
- Overvoltage & Overload Protections
- Thermally-Controlled Cooling Fan
- UL, cUL, TUV, CB & CE Approved
Model No. Output Tol. R & N Eff. SP-300-5 5V@50A ±2% 150mV 77% SP-300-7.5 7.5V@34A ±2% 150mV 81% SP-300-12 12V@24A ±1% 150mV 84% SP-300-13.5 13.5V@21A ±1% 150mV 83% SP-300-15 15V@19A ±1% 150mV 83% SP-300-24 24V@12.5A ±1% 150mV 86% SP-300-27 27V@11A ±1% 200mV 87% SP-300-48 48V@6.25A ±1% 240mV 87%